Overview and Comparison of Power Converter Stability Metrics

Power conversion circuits with control loop(s) are everywhere in electronic systems. We must establish stability and performance metrics for control loops and their circuits. However, generally accepted metrics may not be good enough. Is a crossover frequency with 45 degrees of phase margin and 10 dB of gain margin enough? How can we relate phase margin to peaking in the impedance profile and transient noise requirements? This article aims to answer these and other questions.


Read More
Thumbnail

Characterizing and Selecting the VRM

VRMs and VRM controllers are often selected based on size, efficiency, price, or a relationship with the manufacturer. This often leads to a poor VRM selection, requiring additional engineering resources, greater time to market, as well as, higher BOM costs to correct the deficiencies. In this article, we evaluate the choices, define some useful figures of merit, and provide specific selection suggestions.


Read More
thumb

Target Impedance Limitations and Rogue Wave Assessments on PDN Performance

A common design technique for power distribution networks (PDN) is the determination of the peak distribution bus impedance that will assure that the voltage excursions on the power rail will be maintained within allowable limits, generally referred to as the target impedance. In theory, the allowable target impedance is determined by dividing the tolerable voltage excursion by the maximum change in load current.


Read More
figure15_thumb

Transient Load Tester for Time Domain PDN Validation

Power distribution networks (PDNs) delivering power to ICs in a system need to be thoroughly designed and analyzed in order to make sure any voltage fluctuation on the rail is within the tolerance of every IC connected to that rail.  As ICs on the rail draw power, they generate a voltage fluctuation on the rail.  The PDN must have the capacity to supply enough charge such that the resulting voltage drop is less than the maximum voltage drop each IC on the rail can tolerate.  If voltage fluctuations appear outside IC tolerance limits, a slew of problems can surface such as IC damage, failure, or reduced lifespan.


Read More
thumb

Bode Plots are Overrated

I’m not saying control loop stability isn’t important, of course it is. I am saying that whether your focus is power supply design, power integrity or mixed-signal, the Bode plot probably isn’t going to provide you with a reliable or optimum solution. Here are five major reasons for saying this...